Lebrun Labs Nonanimal Toxicology Testing by the Numbers

High-throughput laboratory assay plates

The Numbers Speak for Themselves

Nonanimal Toxicology Testing, Measured and Proven

Lebrun Labs does not ask you to take our word for it. Here is the data behind our validated nonanimal test methods.

1

OECD Method

OECD TG 496-Accepted Test (OptiSafe EIT)

5-7

Days

Average Report Turnaround

3

Grants

NIH SBIR Awards Received

15+

Papers

Peer-Reviewed Publications

100%

Nonanimal

All Protocols Animal-Free

3

Agencies

Regulatory Bodies Accepting Our Data

Data You Can Submit. Science You Can Trust.

Every metric above is backed by published peer-reviewed research, regulatory validation documents, and NIH grant records. When you submit a Lebrun Labs test report, you are submitting data with a documented scientific pedigree.

Contract Research

Specialized Research Services

Nonanimal ocular, dermal, and biochemical research across eight human tissue compartments: skin, ocular, hepatic, pulmonary, intestinal, renal, neuronal, and cardiac, using both established cell lines and primary human cells.

View all services
Ocular research scientist examining eye tissue sampleOphthalmic & Ocular

Ocular Studies

Mechanistic efficacy and dose-response toxicity profiling of candidate ophthalmic compounds, eye area cosmetics, and ocular-contact materials using both validated cell-free macromolecular platforms and human ocular cell-based models. Delivers quantitative irritation classification, injury-severity scoring, and cytotoxicity data.

Dermal skin research scientist in laboratorySkin & Topical

Dermal Studies

Comprehensive cytotoxicity, corrosion, and irritation assessment of active pharmaceutical ingredients, excipients, and topical formulations using both cell-free InChemico™ biochemical platforms and human cell-based models, including primary keratinocytes, fibroblasts, and reconstructed tissue.

Assay development biochemistry laboratoryCustom Platforms

Assay Development

Custom design and validation of in chemico, in vitro, ex vivo and biochemical assay platforms.

Standardized Test Services

OECD Test Guideline No. 496, OptiSafe Eye Irritation Test

Developed by Lebrun Labs

The OptiSafe Eye Irritation Test™ (OptiSafe EIT™)

Eye irritation test for regulatory use (OECD 496). The OptiSafe EIT™ is highly sensitive and the best choice for eye area cosmetics and personal care products, except those containing metal oxides (e.g., zinc oxide, metals in eyeshadows), which should be tested with IVD EIT. Kits are available at inchemico.co.

The In Vitro Depth of Injury™ Eye Irritation Test (IVD EIT™)

Developed by Lebrun Labs

Now Available!

The In Vitro Depth of Injury™ Eye Irritation Test (IVD EIT™)

The only nonanimal test able to discriminate "Eye Protection Required" vs. no labeling required, distinguishing Globally Harmonized System (GHS) categories NC and 2B from 2A and 1. Broad sensitivity covers the full product spectrum, from cosmetics to strong industrial solvents. High mechanistic relevance makes it a strong choice for ocular drug studies.

Toxic chemical corrosive substance testing

Developed by Lebrun Labs

Now Available!

The DermaSafe Skin Corrosion Test™ (DermaSafe SCT™)

The DermaSafe SCT™ is a nonanimal test that can be used to classify the dermal corrosivity of consumer products and industrial chemicals. Results are often used to support Globally Harmonized System (GHS) safety labeling, product documentation and assign Department of Transportation (DOT) packing groups. The test evaluates the extent of dermal corrosion and relates this to regulatory classifications.

Now Open for Submissions

Submit a Sample for Testing

IVD EIT™ and DermaSafe SCT™ are available now. Get a real-time cost estimate on the submission form before you submit. Volume and multi-test discounts apply automatically.

S-1001

In Vitro Depth of Injury™ Eye Irritation Test (IVD EIT™)

Ocular Irritancy, GHS class prediction, EPA class prediction, mechanistic insights

The only nonanimal test able to discriminate "Eye Protection Required" vs. no labeling required, distinguishing GHS categories NC and 2B from 2A and 1. Broad sensitivity covers the full product spectrum, from cosmetics to strong industrial solvents.

From $4,600/sample (service + materials)
3–6 weeks after sample receipt

Volume discounts: 20% for 3–9 samples · 30% for 10+ · 25% multi-test discount stacks

S-2001

DermaSafe Skin Corrosion Test™ (DermaSafe SCT™)

GHS 1A · 1B+1C · Not Corrosive; DOT Packing Group Assignment

A nonanimal in chemico test for classifying dermal corrosives. Supports GHS Category 1A / 1B+1C / Not Corrosive classification and DOT packing group assignment. Shelf-stable, rapid, high-throughput. Patent pending (WO2024177860A1).

From $2,400/sample (service + materials)
7–10 business days after sample receipt

Volume discounts: 20% for 3–9 samples · 30% for 10+ · 25% multi-test discount stacks

How It Works

1

Submit the form

List each material by name and ID/lot number, select tests, choose a payment method, and agree to terms. You receive a reference number instantly.

2

Ship your samples

Send 2 g or 2 mL per test per sample to our Anaheim, CA lab. Email your tracking number and reference number to [email protected].

3

Payment & intake

An invoice is issued on sample receipt. Work begins once payment is confirmed. PO accounts available; contact [email protected].

4

Receive your report

A full GHS classification report with raw data, histopathology (IVD EIT), and regulatory summary is delivered by email.

Ship to: Lebrun Labs LLC · 3301 E. Miraloma Ave., Suite 194, Anaheim, CA 92806 | Attn: Test Services

Start a Request

Want the data in your own lab? OptiSafe and DermaSafe kits from InChemico.

Get the Data

Latest Lebrun Labs News Items

A Lebrun Labs Company

InChemico, partner website
Share